Connect and Align
Move and connect components, align branches to mains and connect them, swap taps and tees.
- Ribbon group
- ModelKit
- Version
- PluBIM 1.5.0
The Connect and Align group on the PB-Modeling tab puts components in place and connects them. Transition and Offset in this group are described under Transition, Offset.
| You want to … | How |
|---|---|
| Move a component up to another and connect it | MoveConnect |
| Rotate a component, move it up and connect it | AlignConnect |
| Align a component to another in 3D without connecting | Align3D |
| Move a branch so it meets the main | AlignBranch |
| Place a branch sloping down or rising to the main | DownToMain and UpToMain |
| Connect a branch to a sloped main with a 45° wye | WyeToMain |
| Connect a duct to a main duct with a tap | DuctTap |
| Swap a tee for a tap on a duct, or the other way round | TeeTap |
Which elements?
| Command | Works with | Not for |
|---|---|---|
| Runs, fittings, accessories, mechanical equipment and plumbing fixtures with free connectors | Pinned components; connectors that are already connected | |
| Like MoveConnect | Pinned components | |
| Straight pipes, ducts, cable trays and conduits with their fittings and accessories | Components held in place by connections (select them too beforehand) | |
| Pipes, ducts, cable trays and conduits: main and branch | Fittings and equipment | |
| Straight pipes: sloped main and branch | Ducts, conduits, cable trays; vertical runs | |
| Ducts: main duct and branch duct | Pipes, conduits, cable trays | |
| Tees and taps on ducts between three ducts | Pipes; fittings with further components attached |
MoveConnect and AlignConnect
MoveConnect moves a component so its nearest free connector lies on the destination's connector, and connects both. AlignConnect also rotates the component until the connectors face each other.

Click PB-Modeling › Connect and Align › MoveConnect or AlignConnect.
Click the destination first, then the component to move.
If other elements are selected before you start, they move along, e.g. a whole group of runs.
Align3D
Align3D aligns a component to a reference component: afterwards their nearest connector axes lie on one line in 3D. Nothing is connected.
Click PB-Modeling › Connect and Align › Align3D.
Click the reference component, then the component to align.
AlignBranch
AlignBranch moves a branch across its direction until its centre line meets the main. Then you can connect it, e.g. with DuctTap or WyeToMain.


Click PB-Modeling › Connect and Align › AlignBranch.
Click the main, then the branch.
If further components are attached to the branch, they hold it in place. Select these components too before you start; they then move along.
DownToMain and UpToMain
Both place a branch perpendicular to the main. DownToMain gives it a slope down to the main, UpToMain a rise. They share one button; the small arrow below it switches to UpToMain.

Click PB-Modeling › Connect and Align › DownToMain or UpToMain.
Click the main, then the branch.
WyeToMain
WyeToMain connects a branch to a sloped main through a 45° elbow and a 45° wye. The branch keeps its position and slope. The wye points downhill in the flow direction, upward for vent pipes. An existing 90° tee is replaced.

Click PB-Modeling › Connect and Align › WyeToMain.
Click the main, then the branch.
DuctTap
DuctTap connects a branch duct to a main duct with a tap. The tap comes from the routing preferences of the duct type.

Click PB-Modeling › Connect and Align › DuctTap.
Click the main duct, then the branch duct.
If the branch's centre line does not meet the main duct, align it first with AlignBranch.
TeeTap
TeeTap swaps a tee for a tap on ducts, and the other way round.
- Tee → tap: the tee is removed, the two main ducts become one duct, and the branch gets a tap.
- Tap → tee: the tap is removed, the main duct is split at the branch, and a tee connects the three ducts.
The fittings come from the routing preferences of the main duct type. The branch duct keeps its size and system.

- Select tees or taps and click PB-Modeling › Connect and Align › TeeTap. All selected ones are swapped. Without a selection, click the fittings one after another; Esc finishes.
Common problems
“The selected element is pinned. Unpin it and try again.”
The component to be moved is pinned. Unpin it.
“The selected elements have no matching free connectors.” / “The nearest connector is already connected.”
The connectors to be connected are already in use or do not match (e.g. pipe to duct). Disconnect the connector first with Disconnect or choose other components.
“The nearest connectors do not face each other. Use AlignConnect instead.”
MoveConnect only moves. If the connectors point in different directions, use AlignConnect.
“Connected elements stop the branch from moving. …”
Select the connected elements too before AlignBranch.
“The branch centre line does not meet the main. …” / “The height difference between the ducts is too large. …”
Align the branch with AlignBranch or adjust the height, and run DuctTap again.
“The branch cannot reach the main through a 45° wye without running uphill. …”
Check the heights and directions of the main and branch: the branch must be able to slope down to the main.
“Duct type … has no tap in its junction routing preferences. …” / “… has no tee in its junction routing preferences.”
Add a tap or tee family to the routing preferences of the duct type.
PluBIM Help