Connect and Align

Move and connect components, align branches to mains and connect them, swap taps and tees.

Ribbon group
ModelKit
Version
PluBIM 1.5.0

The Connect and Align group on the PB-Modeling tab puts components in place and connects them. Transition and Offset in this group are described under Transition, Offset.

You want to … How
Move a component up to another and connect it MoveConnect
Rotate a component, move it up and connect it AlignConnect
Align a component to another in 3D without connecting Align3D
Move a branch so it meets the main AlignBranch
Place a branch sloping down or rising to the main DownToMain and UpToMain
Connect a branch to a sloped main with a 45° wye WyeToMain
Connect a duct to a main duct with a tap DuctTap
Swap a tee for a tap on a duct, or the other way round TeeTap

Which elements?

Command Works with Not for
MoveConnect, AlignConnect Runs, fittings, accessories, mechanical equipment and plumbing fixtures with free connectors Pinned components; connectors that are already connected
Align3D Like MoveConnect Pinned components
AlignBranch Straight pipes, ducts, cable trays and conduits with their fittings and accessories Components held in place by connections (select them too beforehand)
DownToMain, UpToMain Pipes, ducts, cable trays and conduits: main and branch Fittings and equipment
WyeToMain Straight pipes: sloped main and branch Ducts, conduits, cable trays; vertical runs
DuctTap Ducts: main duct and branch duct Pipes, conduits, cable trays
TeeTap Tees and taps on ducts between three ducts Pipes; fittings with further components attached

MoveConnect and AlignConnect

MoveConnect moves a component so its nearest free connector lies on the destination's connector, and connects both. AlignConnect also rotates the component until the connectors face each other.

Animation: MoveConnect and AlignConnect
Fig. 1 · Animation: click the destination first, then the component; MoveConnect only moves it, AlignConnect rotates it to fit first
  1. Click PB-Modeling › Connect and Align › MoveConnect or AlignConnect.

  2. Click the destination first, then the component to move.

If other elements are selected before you start, they move along, e.g. a whole group of runs.

Align3D

Align3D aligns a component to a reference component: afterwards their nearest connector axes lie on one line in 3D. Nothing is connected.

  1. Click PB-Modeling › Connect and Align › Align3D.

  2. Click the reference component, then the component to align.

AlignBranch

AlignBranch moves a branch across its direction until its centre line meets the main. Then you can connect it, e.g. with DuctTap or WyeToMain.

Animation: AlignBranch
Fig. 2 · Animation: branch higher before, on the main's axis after
Animation: AlignBranch on a riser
Fig. 3 · Animation: vertical main; the branch is moved sideways until its centre line meets the riser
  1. Click PB-Modeling › Connect and Align › AlignBranch.

  2. Click the main, then the branch.

If further components are attached to the branch, they hold it in place. Select these components too before you start; they then move along.

DownToMain and UpToMain

Both place a branch perpendicular to the main. DownToMain gives it a slope down to the main, UpToMain a rise. They share one button; the small arrow below it switches to UpToMain.

Animation: DownToMain
Fig. 4 · Animation: branch perpendicular to the main, sloping down to it (DownToMain)
  1. Click PB-Modeling › Connect and Align › DownToMain or UpToMain.

  2. Click the main, then the branch.

WyeToMain

WyeToMain connects a branch to a sloped main through a 45° elbow and a 45° wye. The branch keeps its position and slope. The wye points downhill in the flow direction, upward for vent pipes. An existing 90° tee is replaced.

Animation: WyeToMain
Fig. 5 · Animation: branch connected to the main through a 45° elbow and a 45° wye
  1. Click PB-Modeling › Connect and Align › WyeToMain.

  2. Click the main, then the branch.

DuctTap

DuctTap connects a branch duct to a main duct with a tap. The tap comes from the routing preferences of the duct type.

Animation: DuctTap
Fig. 6 · Animation: branch duct connected to the main duct with a tap
  1. Click PB-Modeling › Connect and Align › DuctTap.

  2. Click the main duct, then the branch duct.

If the branch's centre line does not meet the main duct, align it first with AlignBranch.

TeeTap

TeeTap swaps a tee for a tap on ducts, and the other way round.

  • Tee → tap: the tee is removed, the two main ducts become one duct, and the branch gets a tap.
  • Tap → tee: the tap is removed, the main duct is split at the branch, and a tee connects the three ducts.

The fittings come from the routing preferences of the main duct type. The branch duct keeps its size and system.

Animation: TeeTap
Fig. 7 · Animation: tee swapped for a tap, then back
  1. Select tees or taps and click PB-Modeling › Connect and Align › TeeTap. All selected ones are swapped. Without a selection, click the fittings one after another; Esc finishes.

Common problems

“The selected element is pinned. Unpin it and try again.”

The component to be moved is pinned. Unpin it.

“The selected elements have no matching free connectors.” / “The nearest connector is already connected.”

The connectors to be connected are already in use or do not match (e.g. pipe to duct). Disconnect the connector first with Disconnect or choose other components.

“The nearest connectors do not face each other. Use AlignConnect instead.”

MoveConnect only moves. If the connectors point in different directions, use AlignConnect.

“Connected elements stop the branch from moving. …”

Select the connected elements too before AlignBranch.

“The branch centre line does not meet the main. …” / “The height difference between the ducts is too large. …”

Align the branch with AlignBranch or adjust the height, and run DuctTap again.

“The branch cannot reach the main through a 45° wye without running uphill. …”

Check the heights and directions of the main and branch: the branch must be able to slope down to the main.

“Duct type … has no tap in its junction routing preferences. …” / “… has no tee in its junction routing preferences.”

Add a tap or tee family to the routing preferences of the duct type.

Related guides